M&S BRACHYTHERAPY SERVICES LLC
TEST REPORT
03/17/03
DR. K's IODOWASH
EQUIPMENT:
1. Ludlum Mod. 14C Geiger counter with Pancake Probe.
2. I-131 RADIOACTIVE LIQUID.
3. Capintec CRC-15 dose calibrator calibrated for Iodine 131.
4. Linoleum tile (unwaxed).
5. Shielded glove box.
PROCEDURE:
1. Place Linoleum in shielded glove box and dispense small amount of I-131 on tile.
2. Allow I-131 to dry for 4 hours.
3. SHAKE WELL and apply IODOWASH to contaminated tile.
4. Let set for 30 sec.
5. Wipe up IODOWASH with paper towels and place in dose calibrator.
6. Record data.
DATA:
I-131 .............1.4 mCi.
Placed on tile.
I-131..............1.4 mCi.
Picked up by IODOWASH.
Geiger counter reading on
tile before decontamination .....>1000 mR/hr (off scale).
Geiger counter reading on
tile after decontamination...... 0.5 mR/hr (equivalent to background readings).
CONCLUSIONS:
The IODOWASH removed all
the I-131 contaminant in one washing.
Respectfully Submitted by:
Bruno J. Schmidt
John Kuperus